|
Series |
Product |
Name |
Summary |
|
|
|
Analog to Digital Converter |
The ADC182 converts a wide range of analog
process signals to 8-bit digital signals, and features: Input
of common AC or DC current and voltage signals, RTD and
thermocouple temperatures, resistance, potentiometer and
frequency signals. |
|
|
|
Analog to Pulse Converter |
The APC253 converts an analog input signal to a
pulse signal, and features: Input include AC/DC current &
volts, resistance, RTD (Pt100), thermocouple, pH/ORP and
pulse. Output up to 10k Hz. Transistor (pulse) output. 0Vrms
isolation. |
|
|
|
Analog to Pulse Converter |
The APC153 converts an analog input signal to a
pulse signal, and features: Input include AC/DC current &
volts, resistance, RTD (Pt), thermocouple, pH/ORP and pulse.
Output up to 10k Hz. Transistor (pulse) output. 2000Vrms
isolation. |
|
|
|
Analog to Resistance |
The ANALOG TO RESISTANCE ATR167 converts most
process signals into a simulated resistance output along with
3-way galvanic isolation up to 2000V RMS. between input
signal, resistance output and power supply. |
|
|
|
Bipolar Signal Converter |
The BSC133 converts uni- & bi-polar input
signals to a bi-polar DC signal, and features: Inputs include
AC/DC current & volts, resistance, temperature RTD (Pt) &
thermocouple, pH/ORP, frequency & pulse, LVDT and millivolts. |
|
|
|
Conductivity Transmitter |
The CDT128 is used to convert conductivity to a
DC signal and features: Any type of conductivity input. Output
up to 18Vdc or 50mAdc. 2000Vrms isolation. Sensor excitation.
Temperature compensation option. |
|
|
|
Dual Channel Isolator |
The DI739 combines two fully independent
isolator channels in one housing. The inputs are factory
configured to customer requirement. Both outputs are coding
plug configurable for common process signals (Factory default
is 4-20mA out). |
|
|
|
LVDT Transmitter |
The LVDT149 converts LVDT to DC signal, and
features: Any type of LVDT input. Output up to 18Vdc or
50mAdc. Output ramp option. Front adjustments for span and
zero. All common AC or DC supplies. |
|
|
|
Multipoint Digital-Analog
Converter |
The MPA166 sums up to 16 digital inputs and
converts the result to a DC signal, and features: All inputs
have an equal weighting, option for alternate input weighting
options. DC input signals can be either voltage or current. |
|
|
|
16-Point Metering Tube Sensor |
The MTS570 is a 16-point Optical Measuring Tube
Sensor that detects a fill level and converts it to a NPN open
collector signal, and uses an 800mm length vertical tube with
16 light sensitive resistance detectors with matching LEDS. |
|
|
|
pH / ORP Transmitter |
The PHT129 converts pH/Redox to DC signal, and
features: Wide range of pH and ORP probe input. Output up to
18Vdc or 50mAdc. 2000Vrms isolation. High input impedance.
Temperature compensation optional. |
|
|
|
Differential Pressure Monitor |
The PM277 converts differential air pressure to
an analog output and provides a relay contact, and features:
Robust piezoresistive silicon pressure sensor for high
accuracy and long life. Wide pressure range from 2kPa to
200kPa. |
|
|
|
Quad Loop Powered Isolator |
The QLPI731 is a four channel loop powered
isolator that combines signal isolation and conversion in one
compact package. Due to its width of only 15mm per channel and
the 35mm DIN-Rail mounting the QLPI731 is a "space saver". |
|
|
|
RTD Temperature Transmitter |
The RTDT225 converts RTD (Pt100) temperature
sensors to DC signal, and features: Any RTD input type. 2-wire
or 3-wire output loop power supplies. Linearization circuit.
Lead resistance compensation. Sensor excitation. |
|
|
|
Signal Splitter |
The SSP235 produces two DC output signals from
one input signal, and features: Inputs include process signals
such as 4-20mA, mV, Bipolar, Thermocouple, RTD, Pulse,
Resistance, AC Current or AC Voltage. |
|
|
|
Zero Speed (Stall) Monitor |
The STM156 is a frequency alarm with an
adjustable trip point, true relay contact output, and
features: Input includes external pulse and any type of speed
sensor. Relay contact output. Front adjustments for trip speed
and start-up delay. |
|
|
|
Thermocouple Transmitter |
The TCT226 converts a thermocouple temperature
input to a DC signal, and features: Input includes Type- J, K,
T, R, N, S & E thermocouples. 2-wire or 3-wire output loop
power supplies. 0Vrms isolation. Cold junction compensation.
|
|
|
|
Triple Trip Alarm |
The TRA173 is a triple relay output with
adjustable set-point and features: Input up to 2kVdc and
10Adc. Contacts rated at 10A/250Vac. Front setpoint
adjustments. Sensor excitation. Trip status is indicated by
LED. |
|
|
|
Universal Signal Conditioner |
Is a one box does all that combines measurement
and control functions in a single instrument and provides user
selectable solutions for most signal conditioning applications
including PID control. |
|
|
|
Vibration Transmitter |
The VBT144 converts vibration to DC signal, and
features: Inputs from swing-coil velocity transducers,
piezoelectric accelerometer and eddy current displacement
probe Zero to peak, peak to peak or RMS average normalized. |
|
|
|
Vibration Transmitter |
The VBT244 converts vibration to DC signal, and
features: 2-wire or 3-wire output loop power supplies Inputs
from swing-coil velocity transducers, quartz shear transducers
and eddy current displacement probe. |