Series

Product

Name

Summary

Analog to Digital Converter The ADC182 converts a wide range of analog process signals to 8-bit digital signals, and features: Input of common AC or DC current and voltage signals, RTD and thermocouple temperatures, resistance, potentiometer and frequency signals.
Analog to Pulse Converter The APC253 converts an analog input signal to a pulse signal, and features: Input include AC/DC current & volts, resistance, RTD (Pt100), thermocouple, pH/ORP and pulse. Output up to 10k Hz. Transistor (pulse) output. 0Vrms isolation.
Analog to Pulse Converter The APC153 converts an analog input signal to a pulse signal, and features: Input include AC/DC current & volts, resistance, RTD (Pt), thermocouple, pH/ORP and pulse. Output up to 10k Hz. Transistor (pulse) output. 2000Vrms isolation.
Analog to Resistance The ANALOG TO RESISTANCE ATR167 converts most process signals into a simulated resistance output along with 3-way galvanic isolation up to 2000V RMS. between input signal, resistance output and power supply.
Bipolar Signal Converter The BSC133 converts uni- & bi-polar input signals to a bi-polar DC signal, and features: Inputs include AC/DC current & volts, resistance, temperature RTD (Pt) & thermocouple, pH/ORP, frequency & pulse, LVDT and millivolts.
Conductivity Transmitter The CDT128 is used to convert conductivity to a DC signal and features: Any type of conductivity input. Output up to 18Vdc or 50mAdc. 2000Vrms isolation. Sensor excitation. Temperature compensation option.
Dual Channel Isolator The DI739 combines two fully independent isolator channels in one housing. The inputs are factory configured to customer requirement. Both outputs are coding plug configurable for common process signals (Factory default is 4-20mA out).
LVDT Transmitter The LVDT149 converts LVDT to DC signal, and features: Any type of LVDT input. Output up to 18Vdc or 50mAdc. Output ramp option. Front adjustments for span and zero. All common AC or DC supplies.
Multipoint Digital-Analog Converter The MPA166 sums up to 16 digital inputs and converts the result to a DC signal, and features: All inputs have an equal weighting, option for alternate input weighting options. DC input signals can be either voltage or current.
16-Point Metering Tube Sensor The MTS570 is a 16-point Optical Measuring Tube Sensor that detects a fill level and converts it to a NPN open collector signal, and uses an 800mm length vertical tube with 16 light sensitive resistance detectors with matching LEDS.
pH / ORP Transmitter The PHT129 converts pH/Redox to DC signal, and features: Wide range of pH and ORP probe input. Output up to 18Vdc or 50mAdc. 2000Vrms isolation. High input impedance. Temperature compensation optional.
Differential Pressure Monitor The PM277 converts differential air pressure to an analog output and provides a relay contact, and features: Robust piezoresistive silicon pressure sensor for high accuracy and long life. Wide pressure range from 2kPa to 200kPa.
Quad Loop Powered Isolator The QLPI731 is a four channel loop powered isolator that combines signal isolation and conversion in one compact package. Due to its width of only 15mm per channel and the 35mm DIN-Rail mounting the QLPI731 is a "space saver".
RTD Temperature Transmitter The RTDT225 converts RTD (Pt100) temperature sensors to DC signal, and features: Any RTD input type. 2-wire or 3-wire output loop power supplies. Linearization circuit. Lead resistance compensation. Sensor excitation.
Signal Splitter The SSP235 produces two DC output signals from one input signal, and features: Inputs include process signals such as 4-20mA, mV, Bipolar, Thermocouple, RTD, Pulse, Resistance, AC Current or AC Voltage.
Zero Speed (Stall) Monitor The STM156 is a frequency alarm with an adjustable trip point, true relay contact output, and features: Input includes external pulse and any type of speed sensor. Relay contact output. Front adjustments for trip speed and start-up delay.
Thermocouple Transmitter The TCT226 converts a thermocouple temperature input to a DC signal, and features: Input includes Type- J, K, T, R, N, S & E thermocouples. 2-wire or 3-wire output loop power supplies. 0Vrms isolation. Cold junction compensation.
Triple Trip Alarm The TRA173 is a triple relay output with adjustable set-point and features: Input up to 2kVdc and 10Adc. Contacts rated at 10A/250Vac. Front setpoint adjustments. Sensor excitation. Trip status is indicated by LED.
Universal Signal Conditioner Is a one box does all that combines measurement and control functions in a single instrument and provides user selectable solutions for most signal conditioning applications including PID control.
Vibration Transmitter The VBT144 converts vibration to DC signal, and features: Inputs from swing-coil velocity transducers, piezoelectric accelerometer and eddy current displacement probe Zero to peak, peak to peak or RMS average normalized.
Vibration Transmitter The VBT244 converts vibration to DC signal, and features: 2-wire or 3-wire output loop power supplies Inputs from swing-coil velocity transducers, quartz shear transducers and eddy current displacement probe.
APCS the Signal Conditioning Specialists